{"product_id":"konmed-km-560-emg-biofeedback-system-for-rehabilitation","title":"Konmed KM-560 EMG Biofeedback System for Rehabilitation","description":"\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eKonmed KM-560 EMG Biofeedback System for Rehabilitation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a multifunctional professional rehabilitation system designed to support \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEMG assessment, biofeedback training, muscle rehabilitation and electrical stimulation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e in clinical environments. The system brings several rehabilitation functions together, including \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEMG Test, EMG Feedback, EMG Game, ETS (EMG Triggered Stimulation), and STIM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, allowing clinicians to select different training and stimulation approaches according to the rehabilitation program. Through real-time EMG monitoring, the system displays muscle activity on its \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e7-inch color high-resolution TFT touchscreen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, enabling the clinician to observe the patient's muscle response during contraction, relaxation and training exercises. The KM-560 also provides patient case management and treatment-record functions, allowing rehabilitation sessions to be organized and reviewed within the device. The system is available in \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e560-2 and 560-4 configurations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing options for professional rehabilitation applications requiring different channel configurations. \u003c\/span\u003e\u003cspan\u003eEMG Biofeedback KM 560(3)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe KM-560 combines \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEMG biofeedback with electrical stimulation-based rehabilitation functions\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing a platform for both muscle activity monitoring and stimulation-assisted training. During EMG biofeedback, the system measures the electrical activity produced by the muscles and presents the information visually, allowing the patient and clinician to observe changes in muscle activity during exercises. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eETS function\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e further connects voluntary EMG activity with electrical stimulation, with stimulation being triggered when the measured EMG signal reaches the selected threshold. The system also includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEMG Game training\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, which uses myoelectric signals as physiological feedback during interactive exercises. In STIM mode, electrical stimulation parameters can be adjusted according to the selected treatment program. These integrated functions make the KM-560 suitable for professional rehabilitation settings where muscle activity assessment, active training, biofeedback and electrical stimulation may be used as part of a structured therapy program. \u003c\/span\u003e\u003cspan\u003eEMG Biofeedback KM 560(3)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0470\/6179\/4980\/files\/KM-560-EMG-Biofeedback-Therapy-System_2_a02c49d7-cf4f-4624-81a1-80e30e508e77.png?v=1791030994\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0470\/6179\/4980\/files\/KM-560-EMG-Biofeedback-Therapy-System_1.png?v=1791030829\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0470\/6179\/4980\/files\/KM-560-Biofeedback-Clinic-Use-System.png?v=1791030828\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0470\/6179\/4980\/files\/KM-560-EMG-Muscle-Stimulation-Device_2.png?v=1791030829\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0470\/6179\/4980\/files\/KM-560-Pelvic-Muscle-Training-System_1.png?v=1791030828\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0470\/6179\/4980\/files\/KM-560-Biofeedback-Clinic-Use-System_17.png?v=1791029293\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0470\/6179\/4980\/files\/KM-560-Clinical-Biofeedback-Device_42.jpg?v=1791029119\" alt=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eEMG Biofeedback Training:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides visual feedback of muscle activity so that muscle performance can be observed during rehabilitation exercises.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eEMG Test Function:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Supports assessment of muscle activity through different testing and evaluation stages.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eEMG Game Training:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Uses myoelectric signals as physiological feedback for interactive rehabilitation training.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eETS – EMG Triggered Stimulation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Connects detected EMG activity with electrical stimulation when the selected threshold is reached.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSTIM Function:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides adjustable electrical stimulation for professional rehabilitation programs.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eReal-Time EMG Monitoring:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Displays muscle activity and EMG waveforms during treatment and training.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e7-Inch Color Touchscreen:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides an easy-to-view interface for treatment operation, parameter adjustment and patient information.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePatient Case Management:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Allows users to create, search and manage patient cases within the system.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTreatment Record Storage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Enables treatment records to be saved and reviewed for patient follow-up.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMultiple Configurations:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Available in 560-2 and 560-4 versions for different professional requirements.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eElectrode Compatibility:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Supports patch electrodes for surface applications.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOptional Probes:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Vaginal and anal probes are available for specific pelvic-floor applications.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eRechargeable Battery:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Supports convenient operation with an internal rechargeable lithium battery. \u003c\/span\u003e\u003cspan\u003eEMG Biofeedback KM 560(3)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan\u003eBenefits\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eReal-Time Muscle Feedback:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides visual information about muscle activity during training, helping the clinician observe the patient's response throughout the session.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSupports Muscle Control Training:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e EMG feedback can be used during contraction and relaxation exercises as part of a structured rehabilitation program.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMultiple Rehabilitation Functions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Combines EMG testing, biofeedback, interactive training, ETS, and stimulation in one system.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSupports Active Rehabilitation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Allows patients to participate in exercises while observing their muscle activity through the displayed EMG feedback.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eEMG-Triggered Stimulation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The ETS function can provide stimulation based on the patient's detected EMG activity and selected threshold.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0470\/6179\/4980\/files\/KM-560-Biofeedback-Clinic-Use-System_14_-_Copy.png?v=1791029295\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0470\/6179\/4980\/files\/KM-560-Portable-Biofeedback-Machine_20_d7ce7629-4724-4edb-9966-43fce44fb504.jpg?v=1791029119\" alt=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAdjustable Treatment Parameters:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Stimulation settings can be adjusted according to the selected therapy program and professional requirements.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSupports Pelvic Floor Rehabilitation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The system can be used for pelvic floor muscle evaluation and training with appropriate electrodes or probes.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSupports Postpartum Rehabilitation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides functions applicable to pelvic floor rehabilitation programs following childbirth.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePatient Record Management:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Treatment information can be associated with patient cases for organized clinical documentation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInteractive Training Option:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e EMG Game functionality provides an additional interactive method of using myoelectric feedback during rehabilitation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eIntegrated System:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Multiple rehabilitation functions are available through a single touchscreen-controlled platform. \u003c\/span\u003e\u003cspan\u003eEMG Biofeedback KM 560(3)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePeripheral Motor Dysfunction Rehabilitation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Can be incorporated into rehabilitation programs focused on peripheral motor function and muscle activity.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eCerebrovascular Accident Rehabilitation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides EMG biofeedback and stimulation functions that can be incorporated into professional rehabilitation programs following cerebrovascular accident.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePelvic Floor Muscle Dysfunction:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Supports assessment and rehabilitation of pelvic floor muscle activity.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePelvic Floor Muscle Evaluation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides EMG-based monitoring for evaluation of pelvic floor muscle activity.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePelvic Floor Therapy:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Can be used as part of professional pelvic floor rehabilitation programs.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eUrinary Incontinence Associated with Pelvic Floor Dysfunction:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Supports rehabilitation programs involving pelvic floor muscle dysfunction associated with urinary incontinence.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePostpartum Rehabilitation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Can be incorporated into pelvic floor rehabilitation programs after childbirth.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBiofeedback Kegel Training:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides EMG feedback for professional Kegel and pelvic floor muscle training.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eEMG Muscle Rehabilitation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Supports rehabilitation exercises where muscle activity is monitored through EMG.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eNeuromuscular Electrical Stimulation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides electrical stimulation functionality for professional rehabilitation applications.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eEMG-Based Rehabilitation Training:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Combines muscle activity monitoring with structured rehabilitation exercises.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePelvic Floor Biofeedback Training:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Can be used with appropriate accessories for pelvic floor biofeedback applications. \u003c\/span\u003e\u003cspan\u003eEMG Biofeedback KM 560(3)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0470\/6179\/4980\/files\/KM-560-Biofeedback-Professional-Training-System_9.png?v=1791029292\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0470\/6179\/4980\/files\/KM-560-Portable-Biofeedback-Machine_13_8081d34a-1583-4211-ac2a-638c75b3f9c2.jpg?v=1791029119\" alt=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBiofeedback Nerve and Muscle Stimulator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKM-560 \/ 560-2 \/ 560-4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7-inch Color TFT Touchscreen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOutput Current\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤50 mA under 500 Ω load\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePulse Width\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50–450 μs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePulse Frequency\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1–120 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTreatment Time\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1–60 minutes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eEMG Measuring Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2–2000 μV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eEMG Resolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤2 μV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSystem Noise\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤1 μV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eEMG Pass Band\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20–500 Hz (-3 dB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCommon Mode Rejection Ratio\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt;100 dB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePower Frequency Filter\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 Hz notch filter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eInternal Battery\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC 14.8 V \/ 2800 mAh rechargeable lithium battery\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAdapter Input\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC 100–240 V, 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAdapter Output\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC 19 V \/ 3 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDevice Size\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e23 × 12 × 20 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 2.4 kg including battery\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eWorking Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5°C–40°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eRelative Humidity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤80%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan\u003eThe above technical parameters are based on the supplied KM-560 product documentation. \u003c\/span\u003e\u003cspan\u003eEMG Biofeedback KM 560(3)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0470\/6179\/4980\/files\/KM-560-Biofeedback-Clinic-Use-System_28.png?v=1791029295\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0470\/6179\/4980\/files\/KM-560-Portable-Biofeedback-Machine_46.jpg?v=1791029119\" alt=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eAccessories\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eMain KM-560 Device\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSquare Patch Electrodes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRectangular Patch Electrodes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eElectrode Connection Wires\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePower Adapter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePower Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptional Vaginal Probe\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptional Anal Probe\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eInstruction Manual EMG\u003c\/span\u003e\u003cspan\u003e Biofeedback KM 560(3)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWhy Choose Konmed KM-560?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eKonmed KM-560 EMG Biofeedback System\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides a combination of assessment, feedback, training and stimulation functions within one professional rehabilitation platform. Its EMG Test and Biofeedback functions allow muscle activity to be monitored during rehabilitation, while EMG Game provides an interactive training option. The ETS function adds EMG-triggered electrical stimulation, and the STIM function provides adjustable stimulation parameters for professional use. The touchscreen interface provides access to these functions while the case and record-management system supports patient documentation and treatment follow-up. With applications covering muscle rehabilitation, pelvic floor rehabilitation, Kegel biofeedback training, postpartum rehabilitation and other documented rehabilitation programs, the KM-560 can be incorporated into different professional physiotherapy and rehabilitation workflows. \u003c\/span\u003e\u003cspan\u003eEMG Biofeedback KM 560(3)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSEO Keywords\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eKonmed KM-560 EMG Biofeedback System, Konmed KM-560 EMG Biofeedback Device, KM-560 Biofeedback Machine, EMG Biofeedback Therapy Equipment, EMG Biofeedback Rehabilitation Device, EMG Muscle Stimulator, EMG Therapy Machine, Biofeedback Nerve and Muscle Stimulator, Neuromuscular Electrical Stimulation Device, NMES Therapy Machine, ETS Therapy Device, EMG Triggered Stimulation, EMG Evaluation System, EMG Muscle Training Device, Pelvic Floor Biofeedback Device, Pelvic Floor Rehabilitation Machine, Pelvic Floor Therapy Equipment, Kegel Biofeedback Device, Urinary Incontinence Therapy Device, Postpartum Rehabilitation Equipment, Neuro Rehabilitation Equipment, Physiotherapy Rehabilitation Equipment, Muscle Rehabilitation Machine, EMG Rehabilitation Equipment, Rehabilitation Clinic Equipment, Professional EMG Biofeedback System, Professional EMG Therapy Equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eTags\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eKonmed KM-560, KM-560 EMG, EMG Biofeedback, EMG Biofeedback Machine, EMG Therapy, Biofeedback System, Muscle Stimulator, EMG Stimulator, NMES, Neuromuscular Stimulation, ETS, EMG Triggered Stimulation, Muscle Training, Muscle Rehabilitation, Pelvic Floor Therapy, Pelvic Floor Rehabilitation, Kegel Training, Urinary Incontinence, Postpartum Rehabilitation, Neuro Rehabilitation, Physiotherapy Equipment, Rehabilitation Equipment, Physiotherapy Machine, EMG Therapy Equipment, Biofeedback Therapy, Konmed, Biotronix\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eAI Image Disclaimer\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e AI-generated or digitally enhanced for marketing, presentation and visualization purposes. These images are intended to provide a general visual representation of the product and its possible rehabilitation environment and should not be considered an exact representation of the supplied device. AI-generated visuals may differ from the actual product in terms of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003edevice configuration, accessories, dimensions, colours, touchscreen interface, electrode placement, patient positioning, treatment setup or clinical environment\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"Biotronix Care International","offers":[{"title":"Default Title","offer_id":53844547371172,"sku":null,"price":225000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0470\/6179\/4980\/files\/BiofeedbackStimulatorKM560-2-05_64989af9-3d52-4594-89f3-4a9080cef858.jpg?v=1791033952","url":"https:\/\/solutionforever.in\/products\/konmed-km-560-emg-biofeedback-system-for-rehabilitation","provider":"A2Z Solution Forever ","version":"1.0","type":"link"}