Konmed KM-560 EMG Biofeedback System for Rehabilitation

Biotronix Care International

  • Rs. 225,000.00
    Unit price per 
Shipping calculated at checkout.

Only 10 left!

The Konmed KM-560 EMG Biofeedback System for Rehabilitation is a multifunctional professional rehabilitation system designed to support EMG assessment, biofeedback training, muscle rehabilitation and electrical stimulation in clinical environments. The system brings several rehabilitation functions together, including EMG Test, EMG Feedback, EMG Game, ETS (EMG Triggered Stimulation), and STIM, allowing clinicians to select different training and stimulation approaches according to the rehabilitation program. Through real-time EMG monitoring, the system displays muscle activity on its 7-inch color high-resolution TFT touchscreen, enabling the clinician to observe the patient's muscle response during contraction, relaxation and training exercises. The KM-560 also provides patient case management and treatment-record functions, allowing rehabilitation sessions to be organized and reviewed within the device. The system is available in 560-2 and 560-4 configurations, providing options for professional rehabilitation applications requiring different channel configurations. EMG Biofeedback KM 560(3)

The KM-560 combines EMG biofeedback with electrical stimulation-based rehabilitation functions, providing a platform for both muscle activity monitoring and stimulation-assisted training. During EMG biofeedback, the system measures the electrical activity produced by the muscles and presents the information visually, allowing the patient and clinician to observe changes in muscle activity during exercises. The ETS function further connects voluntary EMG activity with electrical stimulation, with stimulation being triggered when the measured EMG signal reaches the selected threshold. The system also includes EMG Game training, which uses myoelectric signals as physiological feedback during interactive exercises. In STIM mode, electrical stimulation parameters can be adjusted according to the selected treatment program. These integrated functions make the KM-560 suitable for professional rehabilitation settings where muscle activity assessment, active training, biofeedback and electrical stimulation may be used as part of a structured therapy program. EMG Biofeedback KM 560(3)

Key Features

  • EMG Biofeedback Training: Provides visual feedback of muscle activity so that muscle performance can be observed during rehabilitation exercises.
  • EMG Test Function: Supports assessment of muscle activity through different testing and evaluation stages.
  • EMG Game Training: Uses myoelectric signals as physiological feedback for interactive rehabilitation training.
  • ETS – EMG Triggered Stimulation: Connects detected EMG activity with electrical stimulation when the selected threshold is reached.
  • STIM Function: Provides adjustable electrical stimulation for professional rehabilitation programs.
  • Real-Time EMG Monitoring: Displays muscle activity and EMG waveforms during treatment and training.
  • 7-Inch Color Touchscreen: Provides an easy-to-view interface for treatment operation, parameter adjustment and patient information.
  • Patient Case Management: Allows users to create, search and manage patient cases within the system.
  • Treatment Record Storage: Enables treatment records to be saved and reviewed for patient follow-up.
  • Multiple Configurations: Available in 560-2 and 560-4 versions for different professional requirements.
  • Electrode Compatibility: Supports patch electrodes for surface applications.
  • Optional Probes: Vaginal and anal probes are available for specific pelvic-floor applications.
  • Rechargeable Battery: Supports convenient operation with an internal rechargeable lithium battery. EMG Biofeedback KM 560(3)

Benefits

  • Real-Time Muscle Feedback: Provides visual information about muscle activity during training, helping the clinician observe the patient's response throughout the session.
  • Supports Muscle Control Training: EMG feedback can be used during contraction and relaxation exercises as part of a structured rehabilitation program.
  • Multiple Rehabilitation Functions: Combines EMG testing, biofeedback, interactive training, ETS, and stimulation in one system.
  • Supports Active Rehabilitation: Allows patients to participate in exercises while observing their muscle activity through the displayed EMG feedback.
  • EMG-Triggered Stimulation: The ETS function can provide stimulation based on the patient's detected EMG activity and selected threshold.

  • Adjustable Treatment Parameters: Stimulation settings can be adjusted according to the selected therapy program and professional requirements.
  • Supports Pelvic Floor Rehabilitation: The system can be used for pelvic floor muscle evaluation and training with appropriate electrodes or probes.
  • Supports Postpartum Rehabilitation: Provides functions applicable to pelvic floor rehabilitation programs following childbirth.
  • Patient Record Management: Treatment information can be associated with patient cases for organized clinical documentation.
  • Interactive Training Option: EMG Game functionality provides an additional interactive method of using myoelectric feedback during rehabilitation.
  • Integrated System: Multiple rehabilitation functions are available through a single touchscreen-controlled platform. EMG Biofeedback KM 560(3)

Applications

  • Peripheral Motor Dysfunction Rehabilitation: Can be incorporated into rehabilitation programs focused on peripheral motor function and muscle activity.
  • Cerebrovascular Accident Rehabilitation: Provides EMG biofeedback and stimulation functions that can be incorporated into professional rehabilitation programs following cerebrovascular accident.
  • Pelvic Floor Muscle Dysfunction: Supports assessment and rehabilitation of pelvic floor muscle activity.
  • Pelvic Floor Muscle Evaluation: Provides EMG-based monitoring for evaluation of pelvic floor muscle activity.
  • Pelvic Floor Therapy: Can be used as part of professional pelvic floor rehabilitation programs.
  • Urinary Incontinence Associated with Pelvic Floor Dysfunction: Supports rehabilitation programs involving pelvic floor muscle dysfunction associated with urinary incontinence.
  • Postpartum Rehabilitation: Can be incorporated into pelvic floor rehabilitation programs after childbirth.
  • Biofeedback Kegel Training: Provides EMG feedback for professional Kegel and pelvic floor muscle training.
  • EMG Muscle Rehabilitation: Supports rehabilitation exercises where muscle activity is monitored through EMG.
  • Neuromuscular Electrical Stimulation: Provides electrical stimulation functionality for professional rehabilitation applications.
  • EMG-Based Rehabilitation Training: Combines muscle activity monitoring with structured rehabilitation exercises.
  • Pelvic Floor Biofeedback Training: Can be used with appropriate accessories for pelvic floor biofeedback applications. EMG Biofeedback KM 560(3)

Technical Specifications

Specification Details
Product Type Biofeedback Nerve and Muscle Stimulator
Model KM-560 / 560-2 / 560-4
Display 7-inch Color TFT Touchscreen
Output Current ≤50 mA under 500 Ω load
Pulse Width 50–450 μs
Pulse Frequency 1–120 Hz
Treatment Time 1–60 minutes
EMG Measuring Range 0.2–2000 μV
EMG Resolution ≤2 μV
System Noise ≤1 μV
EMG Pass Band 20–500 Hz (-3 dB)
Common Mode Rejection Ratio >100 dB
Power Frequency Filter 50 Hz notch filter
Internal Battery DC 14.8 V / 2800 mAh rechargeable lithium battery
Adapter Input AC 100–240 V, 50/60 Hz
Adapter Output DC 19 V / 3 A
Device Size 23 × 12 × 20 cm
Weight Approx. 2.4 kg including battery
Working Temperature 5°C–40°C
Relative Humidity ≤80%

The above technical parameters are based on the supplied KM-560 product documentation. EMG Biofeedback KM 560(3)

Accessories

  • Main KM-560 Device
  • Square Patch Electrodes
  • Rectangular Patch Electrodes
  • Electrode Connection Wires
  • Power Adapter
  • Power Cable
  • Optional Vaginal Probe
  • Optional Anal Probe
  • Instruction Manual EMG Biofeedback KM 560(3)

Why Choose Konmed KM-560?

The Konmed KM-560 EMG Biofeedback System provides a combination of assessment, feedback, training and stimulation functions within one professional rehabilitation platform. Its EMG Test and Biofeedback functions allow muscle activity to be monitored during rehabilitation, while EMG Game provides an interactive training option. The ETS function adds EMG-triggered electrical stimulation, and the STIM function provides adjustable stimulation parameters for professional use. The touchscreen interface provides access to these functions while the case and record-management system supports patient documentation and treatment follow-up. With applications covering muscle rehabilitation, pelvic floor rehabilitation, Kegel biofeedback training, postpartum rehabilitation and other documented rehabilitation programs, the KM-560 can be incorporated into different professional physiotherapy and rehabilitation workflows. EMG Biofeedback KM 560(3)

 

SEO Keywords

Konmed KM-560 EMG Biofeedback System, Konmed KM-560 EMG Biofeedback Device, KM-560 Biofeedback Machine, EMG Biofeedback Therapy Equipment, EMG Biofeedback Rehabilitation Device, EMG Muscle Stimulator, EMG Therapy Machine, Biofeedback Nerve and Muscle Stimulator, Neuromuscular Electrical Stimulation Device, NMES Therapy Machine, ETS Therapy Device, EMG Triggered Stimulation, EMG Evaluation System, EMG Muscle Training Device, Pelvic Floor Biofeedback Device, Pelvic Floor Rehabilitation Machine, Pelvic Floor Therapy Equipment, Kegel Biofeedback Device, Urinary Incontinence Therapy Device, Postpartum Rehabilitation Equipment, Neuro Rehabilitation Equipment, Physiotherapy Rehabilitation Equipment, Muscle Rehabilitation Machine, EMG Rehabilitation Equipment, Rehabilitation Clinic Equipment, Professional EMG Biofeedback System, Professional EMG Therapy Equipment.

Tags

Konmed KM-560, KM-560 EMG, EMG Biofeedback, EMG Biofeedback Machine, EMG Therapy, Biofeedback System, Muscle Stimulator, EMG Stimulator, NMES, Neuromuscular Stimulation, ETS, EMG Triggered Stimulation, Muscle Training, Muscle Rehabilitation, Pelvic Floor Therapy, Pelvic Floor Rehabilitation, Kegel Training, Urinary Incontinence, Postpartum Rehabilitation, Neuro Rehabilitation, Physiotherapy Equipment, Rehabilitation Equipment, Physiotherapy Machine, EMG Therapy Equipment, Biofeedback Therapy, Konmed, Biotronix

AI Image Disclaimer

 AI-generated or digitally enhanced for marketing, presentation and visualization purposes. These images are intended to provide a general visual representation of the product and its possible rehabilitation environment and should not be considered an exact representation of the supplied device. AI-generated visuals may differ from the actual product in terms of device configuration, accessories, dimensions, colours, touchscreen interface, electrode placement, patient positioning, treatment setup or clinical environment.


We Also Recommend